| Line Size | 15 NB to 600 NB |
|---|---|
| Connection | Flanged to ASA / BS / DIN / JIS |
| Power Supply | 220 VAC / 24VDC |
| Accuracy | ± 0.5% of FSD |
| Minimum Conductivity | 5 µs/cm |
| Lining | PTFE, EPDM, Rubber |
| Process Temperature | Up to 80°C (Rubber), Up to 150°C (PTFE) |
| Electrodes | SS316, Hastelloy C, Titanium, Monel, Pt-Rh |
| Protection | IP66 / Ex-Proof (Optional: IP68) |
| Flow Units | M3/H, M3/M, M3/S, L/H, L/M, L/S, USG/H, USG/M, USG/S |
| Output | 4–20 mA + HART |
| Relay Output | Batcher |
| Flow Rate Display | 5 Digit LCD |
| Totaliser Display | 10 Digit LCD |
| Communication Port | RS485 (Optional) |
| Lowest Velocity | 0.033 m/s |
| Highest Velocity | 15 m/s |
| Display | 4-line LCD display with flow rate, totalized value, and signal condition |
|---|---|
| Accuracy | ±1.0% |
| Size & Weight | 200 × 92 × 32 mm, 538 g |
| Velocity Range | 0.01 to ±32 m/s |
| Battery Life | Ni-MH battery up to 10 hours continuous operation |
| Pipe Size | 13 mm to 6000 mm |
| Transducer Feature | Magnetic device for installation on metal pipes without mounting belt |
| Data Logger | Records flow rate, date, total flow, signal condition, etc. |
| Response Time | Less than 1 second |
| SS Type Sensor | 15 mm – 100 mm (1/2″–4″) |
| M Type Sensor | 50 mm – 700 mm (2″–28″) |
| L Type Sensor | 300 mm – 6000 mm (12″–240″) |
| Line Size | 15 NB to 600 NB |
|---|---|
| Connection | Flanged to ASA / BS / DIN / JIS |
| Power Supply | 220 VAC / 24VDC |
| Accuracy | ±0.5% of FSD |
| Minimum Conductivity | 5 µs/cm |
| Lining | PTFE, EPDM, Rubber |
| Process Temperature | Up to 80°C (Rubber), Up to 150°C (PTFE) |
| Electrodes | SS316, Hastelloy C, Titanium, Monel, Pt-Rh |
| Protection | IP66 / Ex-Proof (Optional: IP68) |
| Flow Units | M3/H, M3/M, M3/S, L/H, L/M, L/S, USG/H, USG/M, USG/S |
| Output | 4–20 mA + HART |
| Relay Output | Batcher |
| Flow Rate Display | 5 Digit LCD |
| Totaliser Display | 10 Digit LCD |
| Communication Port | RS485 (Optional) |
| Lowest Velocity | 0.033 m/s |
| Highest Velocity | 15 m/s |
| Fluid | Clear Liquids & Gases |
|---|---|
| Viscosity | Up to 20 cP |
| Design Pressure | Up to 25 Kg/cm² |
| Line Size | 15 NB to 200 NB |
| Available Materials | SS304 / SS304L / SS316 / SS316L |
| Connection | Flanged (ASA / BS / DIN), Triclover, Screwed BSP / NPT (M/F) |
| Flow Rate Display | 8 Digit LCD |
| Totalizer Display | 10 Digit LCD |
| Protection | IP66 / Ex-Proof (Optional: IP68) |
| Flow Units | M3/H, M3/M, M3/S, L/H, L/M, L/S, USG/H, USG/M, USG/S |
| Design Temperature | Up to 110°C |
| Power Supply | 220 VAC / 24VDC |
| Output | 4–20 mA + HART |
| Relay Output | Batcher |
| Accuracy | ±1% of FSD (±0.5% on request) |
| Communication Port | RS485 (Modbus) (Optional) |
| Lowest Velocity | 0.1 m/s |
| Fluid | Liquid, Gas, Steam, Saturated Steam, Super Heated Steam |
|---|---|
| Available Material | ASTM A105 / SS304 / SS304L / SS316 / SS316L |
| Power Supply | 24 VDC |
| Relay Output | Low & High Flow Alarm |
| Flow Rate Display | 5 Digit LCD |
| Totalizer Display | 8 Digit LCD |
| Flow Unit | M3/H, M3/M, L/H, L/M, USG/M, Kg/H, Kg/M, t/H, t/M, NM3/H |
| Linearity | 1% |
| Line Size | 15 NB to 300 NB |
| Connection | Flange / Wafer / Triclover |
| Output | 4–20 mA + HART |
| Communication Port | RS485 (Modbus) |
| Temperature Display | 4 Digit LCD |
| Pressure Display | 5 Digit LCD |
| Accuracy | ±1% of FSD |
| Repeatability | 0.33% |